TM 5-4320-275-13 & P
ACCUMULATOR (CONT)
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Pipe plug
Use 1-1/4 inch wrench to remove pipe plug (1)
from accumulator.
2. Nipple
Use pipe wrench to remove nipple (2).
3. Cap screws
Use 3/4 inch socket and handle to remove four
cap screws (3) holding accumulator (8) on pump
4. Accumulator
Remove accumulator (8).
NOTE
Gasket (5), seal plate (6), and check valve assembly (7) may stick to accumulator.
Remove and discard gasket (5). Remove seal plate
(6), and check valve assembly (7) from accu
mulator.
4-54