• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table I. Time Standards-Continued
Chapter 3. BATTERY-CHARGING GENERATOR REPAIR INSTRUCTIONS

Maintenance Manual, Pump, Centrifugal Fresh Water; Gas Driven 2 Wheel Mounted 4 In 500 Gpm, 30 Ft Head Page Navigation
  1    2    3  4  5    6    7    8  
img
. . .
Chapter 2
GENERAL MAINTENANCE INSTRUCTIONS AND TROUBLESHOOTING
Note: No special tools or equipment are needed to perform field and depot maintenance on this centrifugal pump.
2805-209-35 and TM 5-X320-215-12.
5. General
This  chapter  provides  information  useful  in
7. Battery-Charging Generator Fails to Charge
diagnosing and correcting unsatisfactory operation of
the centrifugal pump or any of its components. Each
Probable cause
Possible remedy
trouble symptom stated is followed by a list of probable
Armature defective
Replace the armature
causes of trouble. The possible remedy recommended
Field coils defective
(par. 9).
is described opposite the probable cause.
Brush holders and/or
Replace the field coils
brush tension springs
(par. 9).
6. Engine and Pump
defective
Replace brush holders
and/or brush tension
For engine and pump troubleshooting, refer to TM 5-
springs (par. 9).
AGO 4615A
5


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.