TM 5-3825-270-10
0083
WATER TANK AND SPRAYING EQUIPMENT MAINTENANCE
Immediately following the use of soil stabilization additive or equivalent, the Water Distributor and all spraying
equipment MUST be flushed through all valves and ports that the product came in contact with. The Water Distributor
must be flushed three times using 1,000 gallons (3,785.4 L) of water by using the recommended practice:
Drain all existing material/liquid at the 5" hydrant port
Fill tank with 1000 gallons of water, flush a combined 800 gallons of water through the water turret and
flusher nozzles, drain remaining 200 gallons at 5" hydrant port (C2)
Fill tank with 1000 gallons of water, flush a combined 800 gallons of water through the water turret, flusher
nozzles and hose reel, drain remaining 200 gallons at 5" hydrant port (C2)
Fill tank with 1000 gallons of water, flush a combined 500 gallons of water through the water turret and
flusher nozzles, use 200 gallons to rinse soil additive residue from rear of module using the hose reel, drain
remaining 300 gallons at the 2.5" hydrant ports (C3 and C4), gravity bar and petcocks (P1, P2, P3, P4)
END OF TASK
DEGREASING MACHINE
WARNING
SOLVENT CLEANING COMPOUND (DRYCLEANING SOLVENT)
Solvent cleaning compound MIL-PRF-680 Type II and III may be irritating to the eyes and
skin. Use protective gloves and goggles. Use in a well-ventilated area. Use respirator as
needed. Accidental ingestion can cause irritation of digestive tract and respiratory tract,
may cause lung and central nervous system damage. Can be fatal if swallowed.
Inhalation of high/massive concentrations can cause coma or be fatal. First aid for
ingestion: do not induce vomiting. Seek immediate medical attention. First aid for skin
contact: remove contaminated clothing. Wash skin thoroughly with soap and water. If
symptoms persist, seek medical attention. First aid for eye contact: flush with water for
15 minutes or until irritation subsides. If symptoms persist, seek medical attention. First
aid for inhalation: move to fresh air. If not breathing, provide artificial respiration. If
symptoms persist, seek medical attention. Keep away from open flames and other
sources of ignition. Failure to comply may result in injury or death to personnel.
The flashpoint for Type II solvent cleaning compound is 141 to 198F (61 to 92C), and
Type III is 200 to 241F (93 to 116C).
Improper cleaning methods and use of unauthorized cleaning solvents may result in injury
to personnel and/or damage to equipment.
Fire extinguishers should be placed nearby when using solvent cleaning compound.
Failure to comply may result in injury or death to personnel.
Cloths or rags saturated with solvent cleaning compound must be disposed of IAW
authorized facilities' procedures. Failure to comply may result in injury to personnel.
Eye shields must be worn when cleaning with a wire brush. Failure to comply may result
in injury to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention. Failure to
comply may result in injury or death to personnel.
0083-5