TM 10-4630-207-13&P
0011 00
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM INTERVAL ITEM TO BE
PROCEDURE
EQUIPMENT NOT
NO.
CHECKED OR
READY/AVAILABLE
SERVICED
IF:
21
During
Float Level
Check float level indicator (figure 14, item Tank is full.
Indicator
22
During
Control Panel
Check oil pressure gage (figure 14, item Oil pressure, battery, or
2) and warning light (figure 14, item 3),
temperature warning
light is on.
warning light (figure 14, item 5) and water
gage (figure 14, item 6) and warning light
(figure 14, item 7). Refer any warning light
23
During
Moisture Trap
Check moisture trap sight glass (figure 14, Liquid visible through
item 8) frequently to determine any
sight glass on moisture
24
During
Pressure Gage Monitor pressure gage (figure 14, item 9)
Gage does not show
for required vacuum/pressure readings.
correct pressure or
vacuum readings.
0011 00-16