TM 10-4630-207-13&P
0011 00
Table 1. Preventive Maintenance Checks and Services (PMCS) - Continued.
ITEM INTERVAL ITEM TO BE
PROCEDURE
EQUIPMENT NOT
NO.
CHECKED OR
READY/AVAILABLE
SERVICED
IF:
7
Before
Control Panel
Check control panel (figure 5, item 1) for
Instruments damaged
damaged instruments. Check for presence
or illegible. Keys
of keys (figure 5, item 2). Pull emergency
missing. Emergency
button (figure 5, item 3) out.
button inoperative.
8
Before
Fuel
Check fuel supply (figure 5, item 4) and
Hoses leaking. Loose
Supply/Return
return hoses (figure 5, item 5) for leaks
connection on elbow
Hoses
and tight connection to diesel tank elbow
fitting(s). Class III leaks.
9
Before
Vacuum Pump
Check oil level (figure 5, item 7). Add oil
Oil level below mark on
(SAE 40 Summer, SAE 30 Winter) as
dipstick.
required. Place control handle (figure 5,
10
Before
Moisture trap
Open drain on moisture trap (figure 5,
More than 1 cup of
item 9). Service moisture trap if more than moisture drained from
1 cup of liquid drains from trap. WP 0031 trap.
0011 00-6