TM 10-4630-206-12&P
0008 00
Table 1. Preventive Maintenance Checks And Services (PMCS)
Item
Item to
Not Fully Mission
Interval
Procedure
Number
Check/Service
Capable If:
Tank leaks due to
Check tank for damage that would result in
Before,
damage. Gasket
1
SEP Tank
leaks. Check serviceability of lid gasket (9-
During
damaged or
1-0150-1 and 9-1-0150-2 only).
missing.
Damaged or
Before, SEP Tank Hose
Check inflow and outflow connections and
2
leaking hose
During Connections
ball valve for damage and leaks.
connections.
Damaged box and
Before,
Check box for damage and tripped circuit
3
Circuit Breaker Box
/ or tripped
During
breaker.
breakers.
Before,
Check pump for damage. Ensure proper
Pump damaged, or
4
Pump
During
operation by manually operating pump.
does not operate.
Heating element
Before,
5
Heating Element
Check for damage and proper operation.
missing, damaged
During
or inoperative.
Check lid for damage and proper fit. Also
Before, SEP Tank Lid /
Lid missing or
6
check for presence and proper operation of
During Access Panel
damaged.
retainers.
Heating element
7
with scale or lime
deposits on element.
deposits.
Pump housing with
Clean thoroughly. Remove any deposits on
8
Quarterly Pump housing
scale or lime
pump housing.
deposits.
LUBRICATION INSTRUCTIONS
QDC cap locking arms require three drops general-purpose oil, semi-annually.
0008 00-3/(4 Blank)