TM 10-4320-344-10Table 2-11.ItemNo.8IntervalBeforePreventive Maintenance Checks and services for Pumping AssemblyModel 609-C.(continued)LocationItem toCheck/ServiceTRAILER CHASSISANDENCL-CONTAccess DoorsNot Fully Mis-Proceduresion Capable if:Check that doors can be openedand closed.Check for bent orcracked panels.Check formissing or damaged hinges,latches,and mounting hardware.If door is inoperable ordamaged or parts are missing ordamaged, notify unitmaintenance.9BeforeSafety/BreakawayChains andIntervehicularCableCheck for damaged/broken safetyand breakaway chains.Checkintervehicular cable fordamaged connector and brokenp i n s .If chain is damaged orbroken or intervehicular cableconnector is damaged or hasbroken pin(s), notify unitmaintenance.Chain is damagedor broken.Intervehicularcable connectoris damaged orhas brokenp i n ( s ) .2-43