TM 10-4320-344-10ItemNumber123456789101112DescriptionPUMP DISCHARGE GaugePUMP SUCTION GaugeSTART/STOP KnobSTART ButtonMODE SWITCHFuseMANUAL THROTTLEINCREASE KnobENGINE OIL PRESSUREGaugeEngine Oil PressureBypass SwitchENGINETACHOMETER/HOURMETERENGINE AMMETERAlternator LightTable 2-8. Description of Model US636HCCD-1 Control Panel.FunctionDisplays pump water pressure at discharge outlet.Range is 0 to 200 psi.Displays pump water pressure at suction inlet.Rangeis -30 to 200 psi.Enables operation of START button (4) when in STARTposition.Stops engine when in STOP position.PULLTO START and PUSH TO STOP positions.Used to start engine.START/STOP knob (3) must be inSTART position, then push START button in to startengine.Two-position toggle switch.Used to select engineoperating mode.Set to MANUAL for electric manualmode.Set to NORMAL for electric automatic mode.Provides electrical protection for process controllerand controlling device.Used to control engine speed in electric manual mode.Range is IDLE to HIGH.Displays engine oil pressure.Range is 0 to 150 psi.Overrides oil pressure shutoff switch when startingengine.Push in at same time when pushing STARTbutton (4).Tachometer shows engine rpm.Range is 4 to 30 (X 100)rpm.Hourmeter shows amount of time engine hasoperated. Displays hours and tenths of an hour.Indicates rate of electric output by alternator.Range is -60 to +60 amp.Illuminates when alternator is operating.2-13