Weight ................................................................................................................................ 8 lbs.
Overall dimensions ..................................................................................................9 1/2"H x 7"D
Construction
Housing ................................................................................................................... Nylon
Case.............................................................................................................. ABS Plastic
Specifications (con't)
Incased motor............................................................................................................ Zinc
Shaft............................................................................................................ 416 Stainless
Lip seal & O-ring................................................................................................... Buna N
Operating depth
Beginning min...........................................................1/2"
(water level)
Ending max. ...........................................................3/16"
Power cord set .........................................................................................Neoprene, 8 ft. 3-prong
Discharge
Garden hose...............................................................................................................3/4"
Pipe...............................................................................................................................1"
Performance
GPH IN TOTAL FEET*
3'
5'
10'
15'
20'
23'
1300
1200
960
720
360
0
GPH ratings shown are for 1" pipe. Flow rate is reduced when using garden hose.
Unpacking
Packaged in this carton is one pump and one adapter for use with 3/4" garden hose.
General Safety Information
1.
Know the pump application, limitations, and potential hazards.
WARNING
Do not use in explosive atmospheres. Pump water only with this pump. Failure to follow this
warning can result in personal injury and/or property damage.
2.
Disconnect power before servicing.
3.
Release all pressure within the system before servicing any component.
4.
Drain all water from the system before servicing.
5.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury and/or property damage.
6.
Check hoses for weak or worn condition before each use, making certain that all connections are secure.
7.
Periodically inspect pump and system components. Perform routine maintenance as required. (See
Maintenance.) 8. Provide a means of pressure relief on pumps whose discharge line can be shut off or obstructed.
9.
Personal safety:
a.
Wear safety glasses at all times when working with pumps.