TM 10-4320-315-24
2-23. MAINTENANCE OF ELECTRICAL SWITCH
This task covers:
a.
Remove
b.
Install
INITIAL
SETUP:
Tools
Equipment
Conditions
General Mechanics Tool Kit
Pumping assembly is shutdown (refer to TM 10-4320-
(Item 1, Appendix B)
315-10).
Battery assembly is disconnected (para. 2-16).
Materials/Parts
Tags (Item 21, Appendix C)
a.
REMOVE
. (Figure 2-10).
(1)
Open control panel door (1).
(2)
Tag and disconnect wires. See
wiring diagram
(Figure 2-1, Sheet 1).
(3)
Remove nut (2) and washer (3) on ELECTRICAL switch (5).
Figure 2-10. Electrical (Main) Switch