REMOVAL/INSTALLATION:
NOTE
Once the equipment has been prepared to the equipment condition re-
quirements, there is no further removai/installation procedure required.
INSPECTION:
Live steam used for cleaning shall not exceed 100 psi. Use goggles or
face sheild for eye protection. DO NOT direct live steam against skin.
Death or serious injury could occur if compressed air is directed against
skin. Do not use compressed air for cleaning or drying unless the pres-
sure is/has been reduced to 30 psi or less. When working with com-
pressed air, always use chip guards, eye protection, and other personnal
protective equipment.
a.
Clean crankcase with diesel fuel and a wire brush to remove carbon or oil deposits. Wash thoroughly
with live steam and dry with compressed air.
b.
inspect cylinder sleeve for cracks, warpage, corrosion, scoring, or any other damage. Replace crank-
case and piston if damage is found.
5-49
Figure 5-51. Crankcase