TM 10-4320-226-14
d.
Remove two thrust pads (8).
e.
Remove two studs (9) from rocker bracket (10).
6.6.3.2 Repair.
Do not
Do not
use dry cleaning solvent without proper ventilation and clothing.
smoke or use near open flame or excessive heat.
Dry cleaning
solvent is potentially dangerous to personnel and property.
Clean parts
in a well-ventilated area.
Avoid inhalation of solvent fumes.
Wear
goggles and rubber gloves to protect eyes and skin.
Wash exposed skin
thoroughly.
Flash point of solvent is 100°F to 138°F (38°C to 59°C).
Failure to obey this warning may result in personal injury or death.
a.
Clean parts in solvent.
b.
Inspect bushings (3 and 4) for excessive wear.
Replace if defective.
c.
Inspect studs (7 and 9) for damage.
Replace if defective.
d.
Inspect thrust pads (8) for defects.
Replace if defective.
6.6.3.3 Assembly.
a.
Install
b.
Install
c.
Install
Oil holes
obey this
d.
Install
e.
Install
two studs (9) in rocker bracket (10).
two thrust pad (8).
two studs (7) and lock nuts (6).
in bushing must align with oil holes in rocker arm.
Failure to
warning may cause
press bushing (4)
two bushings (3),
equipment damage.
in each rocker arm (5).
rocker arms (5), washers (2), and nuts (1).
6-18