LO 10-4320-226-12
Clean parts with dry cleaning solvent (SD), type II, or equivalent. Dry before lubricating.
Oil fitters shall be Serviced cleaned changed as applicable, when:
a. They are known to be contaminated, or clogged;
b. Service is recommended by AOAP laboratory analysis, or
c. At prescribed hardtime intervals.
Engine oil must be sampled quarterly as prescribed by DA Pam 738-750.
Before you start your lube service
NEVER
ALWAYS
a. Use wrong type/grade grease.
a. Clean grease fittings before lubrication.
b. Use too much lubricant.
b. Use the lubrication order as your guide.
TOTAL TASK-HOUR
TOTAL TASK-HOUR
TASK HOUR
INTERVAL
TASK-HOUR
INTERVAL
1.0
200
0.1
10
1.5
3000
0.5
100
KEY