INTERVAL
ITEM
NO.
ITEM TO BE INSPECTED
PROCEDURE
Equipment is
Not Ready/
Available
TM 5-4320-306-10
Table 2-2. Preventive Maintenance Checks and Services Continued B Before Operation
B - Before Operation
A - After Operation
D - During Operation
W - Weekly
B
D
A
W
18
Charging Receptacle.
The receptacle
cannot accept the
Check that charging receptacle (1) is securely
charging cable
mounted.
connector. The
batteries cannot
Check cables (2) between the receptacle and
be charged
the batteries for corrosion, wear, and signs of shorts
through the
or improper grounding.
receptacle.
Check that the receptacle is connected and
grounded, according to battery circuit plate (3)
located on the inside top of the battery box.
Check the receptacle for damage that would prevent
connection to the charging cable connector.
TM 5-4320-306-10
2-30