TM 10-4930-236-13&P
REMOVAL OF JUNCTION BOX
a.
Disconnect power cable and ON-OFF cable from junction box receptacles.
b.
Refer to procedures above to remove the K1 relay and RF1 filter.
c.
Unscrew coupling nut (1) from coupling (2) to release elbow (3).
d.
Remove nuts (4), lockwashers (5), flat washers (6) and screws (7).
e.
Lift junction box (8) from bracket carefully while withdrawing the motor leads.
f.
Remove screws (9), lockwashers (10), flatwashers (11), dust cap (12) and receptacle J1 (13) with
leads (14 and 15).
g.
Remove screws (16), lockwashers (17), flat washers (18), dust cap (19) and receptacle J2 (20) with
leads (21 and 22).
h.
Remove screws (23), washers (24) and leads (21 and 22).
i.
Remove coupling (2) and vent plugs (25) from junction box (8).
4-30