TM 10-4320-344-24
2.11.2 Stud and Thread Repair. (Continued)
Compressed air can blow dust into the eyes.
Wear eye protection.
Do not
exceed 30 psi (207 kPa) air pressure.
b .
Clean newly bored hole using compressed air.
c.
Lubricate thread cutting tap (3) with transmission oil.
d .
Using tap handle and tap (3), cut new threads.
Compressed air can blow dust into the eyes.
Wear eye protection.
Do not
exceed 30 psi (207 kPa) air pressure.
Dry cleaning solvent is highly toxic and can
ignite organic materials, nitrates, carbides, and chlorates.
Wear
eye, skin, and respiratory protection.
Use only in well ventilated
area.
e .
Using compressed air, blow out dirt and any loose metal chips in threads.
f .
Using rag dampened with cleaning solvent, clean hole.
2-42