TM 10-4320-315-24
2-36. MAINTENANCE OF MAGNETIC PICKUP UNIT (MPU)
This task covers:
a.
Remove
b.
Install
INITIAL SETUP:
Tools
Equipment Conditions
General Mechanics Tool Kit
Pumping assembly is shutdown (refer to TM 10-4320-
(Item 1, Appendix B)
315-10).
a. REMOVE. (Figure 2-23)
(1)
Open engine access door (1).
(2)
Disconnect cable (2) from MPU (3).
(3)
Loosen jam nut (4).
(4)
Unscrew MPU (3) from engine bell housing (5).
b. INSTALL.
(1)
Install MPU (3) on engine bell housing (5) until it makes contact with gear tooth, then back off one-quarter
turn.
(2)
Tighten jam nut (4) maintaining one-quarter turn clearance between MPU and gear tooth.
(3)
Connect wiring harness (2) to MPU (3).
(4)
Close engine access door (1).
2-64