TM 10-4320-309-14
TM 4320-14/1
Item
No.
5
Table 3-2. Unit Preventive Maintenance Checks and Services - Continued
Interval
Semiannually
ITEM TO BE INSPECTED
PROCEDURES
Valve Rocker Arm Clearance
Remove bolts (1) and rocker arm cover (2).
For detailed adjusting procedure, refer to para 3-22.
Not Fully Mission
Capable If:
Valve clearance is not
0.006 inch (0.15mm).
3-12