TM 10-4320-307-24
2-12.2 INSTALLATION OF SUCTION AND DISCHARGE NOZZLE ADAPTERS.
a.
Remove flange covers from pump suction and discharge ports.
NOTE
The installation of suction and discharge nozzle adapters are identical. Only the discharge
nozzle Installation is presented.
b.
Remove nozzle adapters (1) from their storage position.
c.
Position nozzle adapter at pump flange (2). Align mounting holes on neck and pipe (3) with mounting plate on
skid (4). Secure to skid with four screws (5) and washers (6); do not fully tighten.
d.
Position gasket (7) on pump flange (2) and then secure nozzle adapter (1) to flange with 12 screws (8),
washers (9), and nuts (10).
e.
Tighten four screws (5) and washers (6).
2-10