LUBRICATION ORDER
LO5-4320-215-12
23 May 1978 (Supercedes LO 5-4320-215012, 17 February 1961)
PUMP, CENTRIFUGAL: FRESH WATER; GASOLINE DRIVEN;
2 WHEEL MOUNTED; 4 IN.; 500 GPM; 30 FT HEAD
(CARVER MODEL K400S) W/WISCONSIN
ENGINE MODEL MVF4D
Reference: C9100-IL
Intervals and related task-hour times are based on
indicated by dotted arrow shaft on both sides of
normal hours of operation. The task-hour time specified
equipment. Clean parts with SOLVENT, dry cleaning, or
is the time you need to do all the service prescribed for
with 01 L, fuel, dies 81. Dry before lubricating. Drain
a particular interval.
Change the interval if your
crankcase when HOT. Fill and check level. The lowest
lubricants are contamin-ated or if you are operating the
level of maintenance authorized to lubricate e point is
equipment under adverse operating conditions,
indicated by one of the following: (C) Operator/crew or
including longer-than-usual operating hours. You may
(O) Organizational Maintenance.
extend the interval during periods of low activity, but you
You can help improve this publication. If you find any
must take adequate preservation precautions.
mistake or if you know of a way to improve the
* The time specified is the time required to perform all
procedures phase let us know. Your letter or DA Form
services at the particular interval.
2028 (Recommended Changes to Publications and
Blank Forms) should be mailed directly to: Commander,
Clean fittings before lubricating. Relubricate all areas
U.S. Army Troop Support & Aviation Materiel Readiness
exposed to water after amphibious operation. Lubricate
Command, ATTN: DRSTS-MTPS, 4300 Goodfellow
points
Blvd. St. Louis, MO 63120. A reply will be furnished to
you."
*TOTAL TASK-HR
*TOTAL TASK-HR
INTERVAL
TASK-HR
INTERVAL
TASK-HR
10
0.5
250
0.1
50
0.4
1000
0.5
100
0.5
LUBRICANT
INTERVAL
INTERVAL
LUBRICANT
Oil Filter
Crankcase Oil Fill and
(Disassemble, clean
Breather Cap
housing, renew element
(Clean and re-oil)
and reassemble)
(See key) (O)
Air Cleaner
(Refill oil reservoir to full
mark; every 50 hours dis-
Pump Seal Grease Cup (O)
assemble entire unit,
(Refill when wing nut
(O) clean, re-oil and
reassemble. (See key)
Starter
Wheel Bearings
(Remove wheel, clean, inspect
DO NOT LUBRICATE
reassemble) (O)
(O) (Sparingly)
Crankcase Oil Drain Plug
(O) (Drain and refill)
Card 1 of 2